Service available now · 50 states Mon–Sun · 7AM–9PM EST

Bosch E014 — Oven temperature sensor short circuit — sensor reading too low resistance

Complete diagnostics and troubleshooting guide for Bosch range error code E014. Learn what it means, what causes it, and whether you need professional repair.

Severity Medium Repair Needs technician Components Oven temperature sensor, wiring harness

Schedule Bosch
appliance repair

Certified technicians in all 50 US states. Average response within 24 hours.

  • Certified Bosch specialists
  • Genuine OEM parts
  • 30-day labor warranty
  • Upfront flat-rate pricing

E014 at a glance.

Error code E014
Appliance type Range
Severity Medium
Repairability Needs technician
Affected components Oven temperature sensor, wiring harness

Understanding error code E014.

Oven temperature sensor short circuit — sensor reading too low resistance

What E014 means on your Bosch range

Error code E014 is the counterpart to E012 (open circuit). While E012 means the sensor circuit is broken, E014 means the sensor’s resistance is too low — a short circuit condition. The board reads near-zero ohms instead of the expected 1,000+ ohms, which it interprets as an extremely high temperature. The board shuts down heating as a safety measure.

Symptoms

  • The oven won’t heat — same as E012
  • E014 on the display when oven mode is selected
  • The display may show an extremely high temperature reading

Common causes

  • Shorted sensor probe — moisture inside the sensor probe creates a low-resistance path between the wires
  • Pinched sensor wire — the wire passing through the oven wall is compressed, causing the two conductors to touch
  • Corroded connections — corrosion at the plug creates a conductive bridge between the two terminals

Troubleshooting steps you can try

  1. Inspect the sensor connector — unplug the sensor at the back and look for visible corrosion or moisture.
  2. Dry the connector — if moisture is present, dry it thoroughly and reconnect.
  3. Power reset — unplug for 60 seconds after drying the connector.

When to call a technician

Same repair as E012 — the sensor needs testing and likely replacement. A technician will measure resistance (a shorted sensor will read near 0 ohms instead of ~1,100 ohms at room temperature). If the sensor tests normal when disconnected, the wiring has a short that needs tracing. Codes may vary by model generation and series.

Need help? Schedule Bosch Range repair with a certified technician, or contact our team for a free diagnosis consultation.

Can't resolve E014? Our certified technicians diagnose and repair every Bosch range — current production, discontinued, and legacy units. Schedule service or call us for expert help.